Panic hardware installation — Burnaby, BC
- Type:
- Hollow metal door — exit device installation
- Size:
- 36 in × 84 in (single leaf)
- Age:
- Door approximately 5 years; no previous exit device
The problem
A commercial tenant had received a notice from their building inspector requiring panic hardware on a rear exit door. The door had a standard lever handle and deadbolt. The occupant load in the space exceeded the threshold requiring panic hardware under the BC Building Code.
Diagnosis
Existing lever handle and deadbolt removed. Door and frame inspected — hollow metal door and frame in good condition, suitable for exit device installation. Rim exit device selected (surface-mounted, no mortise required). Door edge and frame confirmed compatible with rim device strike.
Products and hardware installed
Products installed
Von Duprin 98 Series rim exit device, Satin Stainless finish. Matching exterior trim with key cylinder for re-entry. Strike and mounting hardware.
Hardware notes
Existing deadbolt removed. Lever handle removed. Cylinder from existing deadbolt re-used in exterior trim for key continuity.
Safety checks completed
Exit device tested — door opens with single motion push on bar. Latch confirmed — door latches on close. Key cylinder tested from exterior. Door and frame alignment confirmed — no binding.
Outcome
Exit device installed and functional. Tenant was provided with documentation of the installation for their building inspector. Warranty: 1-year labour, manufacturer warranty on exit device.
- Duration:
- 2 hours
Need similar work done?
Call Surrey Doors Ltd. for a same-day assessment. We serve Surrey and the Lower Mainland.