Off-track door after cable failure — Whalley, Surrey
- Type:
- Steel sectional, single
- Size:
- 9 ft × 7 ft
- Age:
- Approximately 9 years
The problem
The left cable had snapped and the door had come off the bottom roller bracket on the left side. The door was hanging at an angle and could not be opened or closed. The homeowner had attempted to push it back onto the track, which had bent the bottom section slightly.
Diagnosis
Left lift cable had snapped at the drum — the cable end had frayed over time. The door coming off track had bent the left vertical track at the bottom. The bottom section had a minor crease from the homeowner's attempt to re-track it manually. The crease was cosmetic and did not affect operation. Both cables were replaced (right cable showed similar fraying at the drum). Left vertical track straightened. Bottom roller bracket re-secured.
Products and hardware installed
Products installed
Both lift cables replaced. Left vertical track straightened and re-secured. Bottom roller bracket replaced on left side.
Hardware notes
Torsion spring inspected — in good condition, no replacement needed. All rollers inspected — acceptable wear.
Safety checks completed
Cable drums confirmed properly seated. Door re-tracked and tested through full travel. Balance tested. Opener force limits checked. Auto-reverse tested.
Outcome
Door operating normally. Minor cosmetic crease on bottom section noted on invoice — homeowner declined panel replacement at this time. Warranty: 1-year labour, 1-year parts.
- Duration:
- 2 hours
Need similar work done?
Call Surrey Doors Ltd. for a same-day assessment. We serve Surrey and the Lower Mainland.